Skip to main content

How to connect: Madic Group

Connect your Madic Group PULSE charger to Plugchoice via its SD card configuration.

Requirements

  • A laptop with an SD card reader and a text editor

  • Physical access to the charger's CPU (OCPP kit)

  • The charger's serial number and maximum power


Connect your charger

  1. Take the SD card from the OCPP kit on the charger's CPU.

  2. Open the config.exp file in a text editor.

  3. Set ChargeboxId to the serial number.

  4. Set OCPP_SERVER_URL to: ws://proxy.plugchoice.com/v1

  5. Set VersionOCPP to OCPP1.6.

  6. Set PDL_Power to the charger's maximum power.

  7. Save the file in ANSI encoding. Other encodings break the configuration.

  8. Rename the file to config.csv.

  9. Put the SD card back and power on the charger.

The configuration uploads automatically at power-on.


Registering your charger in Plugchoice

  1. Add the charger using the chargepoint ID. For Madic, this is the serial number you set as ChargeboxId (case sensitive).

Done! The charger should come online.


Troubleshooting

Did you set everything up correctly, but the charger still remains "Pre-registered"?

  • The chargepoint ID in Plugchoice must exactly match the ChargeboxId.

  • Check the file is saved in ANSI encoding and named config.csv.

  • Check the SD card is seated correctly in the OCPP kit.

  • Power cycle the charger after changing the file.

For a complete guide, see our troubleshooting article if your charger can't connect to Plugchoice.

Did this answer your question?